Patient Monitors YR02170 // YR02171 // YR02172

Manufacturer: Kalstein

Description

The Patient Monitors YR02170, YR02171, and YR02172 are sophisticated medical devices designed to provide continuous and multi-parameter monitoring, making them indispensable in clinical settings. Featuring a multi-channel display, these monitors offer a big font interface for enhanced readability, alongside ST and arrhythmia analysis for accurate cardiac assessments. Equipped with drug dose calculation, an OxyCRG dynamic view, and precise respiration monitoring with apnea alarms, these monitors ensure comprehensive patient care. Additionally, they offer NIBP overpressure protection and support both wired and wireless network connectivity, enhancing their versatility and adaptability in various medical environments.

Market Price

The Patient Monitors YR02170, YR02171, and YR02172 are competitively priced within the range of $900 to $1700 USD in the market. This price band reflects their advanced features and the reliability they offer in patient monitoring. By investing in these monitors, healthcare providers can ensure top-notch care and efficiency.

Frequently Asked Questions

What parameters do these monitors track? The monitors track vital parameters such as ECG, heart rate, respiration, SPO2, NIBP, and temperature, providing comprehensive data for patient assessment.

Are the monitors suitable for all patient ages? Yes, these monitors are equipped to handle a wide range of patient ages, from neonates and pediatrics to adults, ensuring versatile use in various medical settings.

How are they powered? The units come with plug-in rechargeable batteries and can operate on both AC and DC, offering flexibility depending on the medical environment.

Advantages and Disadvantages

Advantages: The primary benefits of these patient monitors include precision, ease of use, and connectivity. Their big font interface and multi-channel capabilities allow for efficient monitoring and data interpretation. The inclusion of both wired and wireless network support adds to their efficiency.

Disadvantages: One potential drawback could be the initial cost of investment and the need for regular maintenance to keep the monitors in optimal condition.

Usage in the Field

In practical scenarios, the Patient Monitors YR02170, YR02171, and YR02172 are crucial in intensive care units, emergency rooms, and during surgical interventions. Their ability to deliver real-time, accurate data allows clinicians to make informed decisions quickly, thereby improving patient outcomes.

Recommendations

To optimize the use of these patient monitors, regular calibration and software updates are recommended. Also, proper training for healthcare personnel on the full capabilities and functions of the monitor can enhance its use efficiency.

Features

  • Multi-channel display
  • Big font interface
  • ST and arrhythmia analysis
  • Drug dose calculation and titration table
  • OxyCRG dynamic view display
  • Respiration monitoring with apnea alarms
  • Alarm review, arrhythmia review
  • NIBP overpressure protection
  • Plug-in rechargeable battery, AC/DC available
  • Supporting wire or wireless network

Technical Specifications

Model YR02170 YR02171 YR02172
ECG
Lead mode 5 Leads(RA,LA,LL,RL,V)
Connection method I, II, III,AVR,AVL,AVF,V
Lead Mode 3 Leads (RA,LA,LL)
Connection method I, II,III
Waveform 1ch
Gain x250, x500, x1000, x2000
HR Range Adult: 15~300bpm
Neo/Ped 15~350bpm
Accuracy ±1% or ±1bpm
Resolution 1bpm
Sensitivity >200(uVp-p)
Differential input impedance ≥5MΩ
ST segment Monitoring Range
Measure Range -2.0~+2.0mV
Measure Accuracy -0.8mV~+0.8mV
Heart Rate
Measuring range 0~350bpm 20~300bpm
Accuracy ±1bpm
Resolution 1bpm
Sensitivity >200UVp-p
Respiration
Method Impedance between R-F(RA-LL)
Differential Input Impedance >2.5MΩ
Measuring Impedance Range 0.3~3.0 MΩ
Base line Impedance Range 200~4000Ω
Bandwidth 0.1~2.5Hz
Resp. Rate Adult: 2~120BrPM
Neo/Ped 2~150BrPM 0~150BrPM
Resolution 1 BrPM
Accuracy ±2 BrPM
Alarm 10~40S
NIBP
Method Oscillometric
Mode Manual/Auto/STAT
Measuring Interval in AUTO Mode 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min)
Measuring Period in STAT Mode 5 Min
Pulse Rate Range 40~240bpm
Alarm Type SYS, DIA, MEAN
Resolution
Pressure 1mmHg
Accuracy Maximum Mean error: 5mmHg
Maximum Standard deviation 8mmHg
SPO2
Display Number of SPO2,waveform of capacity,Pulse
Measuring range 0~100%
Resolution 1%
Accuracy 70~100% (±2%)
Alarm system Audio-video alarm
Pulse rate range 0~300bpm
TEMP
Channel 2
Measuring and Alarm Range 0~50ºC
Resolution 0.1ºC
Accuracy 0.1ºC
Actualization interval about 1 Second.
Average Time Constant <10 Second.

Additional information

Weight N/A
Dimensions N/A
Model

YR02170, YR02171, YR02172

Quote List

Quote List

No products in the list

Product categories

In this section you can select the sector or product of your interest.

FAQ

Do you need help?

If you have any questions before processing the order, take a look at the most frequently asked questions

Do you want to know the cost of air shipping to your establishment?

Place your address in the payment area and you will automatically see the shipping to your door!

I am an institution; I need to know the price for several units; I would like to know the cost of the maritime freight

Request a custom quote in the contact section once you identify the model.