Description
Biomedical Liquid Nitrogen Storage Solutions YR05423 // YR05437 offer cutting-edge technology for storing and supplying liquid nitrogen (LN2). These units are constructed with a robust stainless steel design that is both durable and reliable, ensuring safety in even the harshest environments. Featuring innovative pressure-generating technology, they efficiently discharge LN2 into external containers with storage options ranging from 5 to 500 liters. The product line includes comprehensive safety mechanisms, making it suited for a wide array of biomedical applications.
Market Price
The Biomedical Liquid Nitrogen Storage Solutions typically range from $1,600 to $2,300 in the market, aligning with competitive pricing standards for advanced LN2 storage units. Pricing varies based on specific model configurations and features. Please contact us for detailed pricing or further inquiries about potential bulk order discounts.
Frequently Asked Questions
- What is the warranty period for these units? All models come with a 5-year vacuum warranty, ensuring durability and reliability over time.
- Are there any safety features included? Yes, each model is equipped with multiple safety mechanisms, including safety valves and pressure relief systems.
- What is the typical delivery time for these products? Delivery time may vary based on your location and order size. Please check with our sales team for precise timelines.
Advantages and Disadvantages
The advantages of using the Biomedical Liquid Nitrogen Storage Solutions include reduced evaporation loss rates compared to conventional insulation tanks, robust stainless steel construction for enhanced durability, and a variety of accessories like pressure valves and gauges
One potential disadvantage might be the initial investment required for high-quality storage solutions, but the long-term benefits in terms of efficiency and safety can outweigh this.
Product Use in the Field
Typically utilized in medical and laboratory settings, these LN2 storage solutions are designed to securely store and dispense liquefied gas essential for cryogenic applications. Whether preserving biological samples or supporting laboratory procedures, the variants ensure that LN2 is readily available and safely managed.
Recommendations
To ensure maximum efficiency and longevity, it is recommended to regularly inspect valves and gauges on your Biomedical Liquid Nitrogen Storage Solutions. Proper and consistent maintenance can help prevent any potential mishaps or malfunctions. Additionally, staff should be adequately trained in handling and safety procedures relevant to LN2.
Features
- Storage capacities range from 5 to 500 liters
- 5-year vacuum warranty
- Stainless steel construction
- Integrated safety mechanisms
- Individualized valve labeling for easy identification
Technical Specifications
Model | YR05423 | YR05424 | YR05425 | YR05426 | YR05427 | YR05428 | YR05429 | YR05430 |
Performance | ||||||||
LN volume (L) | 5 | 15 | 30 | 50 | 100 | 150 | 200 | 300 |
Static Evaporation (L/Day) | 0.15 | 0.38 | 0.75 | 1 | 1.3 | 1.95 | 2.4 | 3.3 |
LN output (l/min) | 2 | 2 | 3 | 3 | 4 | 6 | 8 | 8 |
Dimensions | ||||||||
Height (mm) | 510 | 750 | 879 | 991 | 1185 | 1188 | 1265 | 1459 |
Outer diameter (mm) | 329 | 404 | 454 | 506 | 606 | 706 | 758 | 857 |
Curb weight (kg) | 15 | 23 | 32 | 54 | 75 | 102 | 130 | 202 |
Complete weight (kg) | 19.1 | 35.3 | 56.6 | 95 | 157 | 225 | 296 | 448 |
Shipping weight (kg) | 28 | 34 | 47 | 63 | 98 | 132 | 164 | 232 |
Pressure parameters (MPA) | 1. Standard working pressure 0.05, 2. Maximum working pressure 0.09, 3. First stage safety valve relief pressure 0.099, 4. Second stage safety valve release pressure 0.15, 5. Pressure gauge range 0~0.25 |
1. Standard working pressure 0.05, 2. Maximum working pressure 0.09, 3. First stage safety valve relief pressure 0.099, 4. Second stage safety valve release pressure 0.15, 5. Gauge range 0-0.25, 6. Rupture disc bursting pressure 0.47 . |
||||||
Model | YR05431 | YR05432 | YR05433 | YR05434 | YR05435 | YR05436 | YR05437 | |
Performance | ||||||||
LN volume (L) | 500 | 100 | 200 | 240 | 300 | 300 | 500 | |
Static Evaporation (L/Day) | 5.5 | 1.3 | 2.4 | 2.9 | 3.3 | 3.3 | 5.5 | 5.5 |
LN output (l/min) | 10 | 4 | 8 | 8 | 8 | 8 | 10 | 10 |
Dimensions | ||||||||
Height (mm) | 1576 | 1185 | 1265 | 1350 | 1459 | 1459 | 1576 | 1576 |
Outer diameter (mm) | 1008 | 606 | 758 | 758 | 857 | 857 | 1008 | 1008 |
Curb weight (kg) | 255 | 75 | 130 | 148 | 202 | 202 | 255 | 255 |
Complete weight (kg) | 665 | 157 | 296 | 350 | 448 | 448 | 665 | 665 |
Shipping weight (kg) | 324 | 98 | 164 | 177 | 232 | 232 | 324 | 324 |
Pressure parameters (MPA) | 1. Standard working pressure 0.05, 2. Maximum working pressure 0.09, 3. First stage safety valve relief pressure 0.099, 4. Second stage safety valve release pressure 0.15, 5. Gauge range 0-0.25, 6. Rupture disc bursting pressure 0.47 . |
1. Standard working pressure 0.05, 2. Maximum working pressure 0.09, 3. First stage safety valve relief pressure 0.099, 4. Second stage safety valve release pressure 0.15, 5. Pressure gauge range 0~0.25 |
1. Standard working pressure 0.05, 2. Maximum working pressure 0.09, 3. First stage safety valve relief pressure 0.099, 4. Second stage safety valve release pressure 0.15, 5. Gauge range 0-0.25, 6. Rupture disc bursting pressure 0.47 . |